MRCOOL® Hyper Heat Central Ducted
24K, 36K, 48K, 60K
Professional HVAC Technician Required
The MRCOOL Central Ducted Hyper Heat System is an innovative HVAC solution designed to provide efficient heating and cooling for residential and commercial spaces. This system is particularly notable for its advanced technology, energy efficiency, and versatility in installation. Here’s a detailed look at what makes the MRCOOL Central Ducted Hyper Heat System stand out:
Key Features
-
Designed for Extreme Climates:
- Designed to conquer extreme seasonal fluctuations, this unit is a reliable choice for both harsh winters and scorching summers. It ensures consistent comfort with outdoor temperatures ranging from -22°F to 122°F.
-
Advanced Technology:
- Featuring a cutting-edge DC Inverter and variable speed technology, it achieves remarkable efficiency, translating into substantial savings on your utility bills while maintaining peak performance.
-
High Efficiency Ratings:
- With an impressive SEER2 rating of up to 17.4 and an HSPF2-4 rating of up to 10, this system ensures indoor comfort and energy savings.
-
No-Vac® Quick Connect® Line Set (Sold Separately):
- Professional HVAC technicians will find installation a breeze with the MRCOOL® No-Vac® Quick Connect® Line Set, an exclusive feature that eliminates the need for vacuuming or flare welding. Its kink-resistant design speeds up the connection process, ultimately reducing installation costs.
-
Eco-Friendly Operation:
- The system operates with the eco-friendly R-410A refrigerant, ensuring minimal environmental impact while maintaining high performance.
-
Durability:
- Crafted from premium materials like painted galvanized steel, the MRCOOL system is built to withstand harsh conditions, providing dependable performance against weather, wildlife, and yard equipment.
-
Quiet Operation:
- MRCOOL systems are engineered to operate quietly, making them a perfect choice for homes and offices where noise reduction is a priority. Advanced fan and compressor technology minimizes operational noise, ensuring a peaceful environment.
-
Smart Control:
- These systems are compatible with smart thermostats and can be controlled remotely via mobile apps. This provides users with the convenience of adjusting their home’s climate from anywhere, optimizing energy usage and enhancing comfort.
Benefits
-
Comfort:
- The hyper heat technology ensures consistent indoor temperatures, providing comfort throughout the year, regardless of external weather conditions.
-
Cost Savings:
- The high energy efficiency of the system results in lower utility bills. Additionally, the durability of the system reduces the need for frequent repairs or replacements.
-
Environmental Responsibility:
- By using less energy and operating with the eco-friendly R-410A refrigerant, the MRCOOL Central Ducted Hyper Heat System reduces its carbon footprint.
-
Enhanced Air Quality:
- The system can be paired with advanced filtration options to improve indoor air quality, reducing allergens, pollutants, and improving overall health and well-being.
-
Warranty:
- In the unlikely event of any issues, enjoy peace of mind with a comprehensive 10-year warranty covering the compressor, parts, and labor. Plus, there's no need for a time-consuming registration process—the labor warranty is automatically activated upon installation.
The MRCOOL Central Ducted Hyper Heat System represents a significant advancement in HVAC technology, offering reliable, efficient, and versatile heating and cooling solutions. Its ability to maintain performance in extreme temperatures, coupled with energy efficiency, smart controls, and eco-friendly operation, makes it a standout choice for both residential and commercial applications. Trust in MRCOOL® and Home of Prefab for top-notch climate control solutions that provide comfort, savings, and peace of mind.
Highlights
MRCOOL® Hyper Heat Central Ducted Product Highlights
Mobile Home Approved
The Central Ducted Hyper Heat Air Handler is made to accommodate the high static requirements for manufactured and modular homes.
Multi-Positional
This unit is compatible with upflow, downflow and horizontal configurations.
Enhanced Heating
Winter Comfort: Long after other heat pumps have been stopped in their tracks by winter weather, the MRCOOL® Central Ducted Hyper Heat keeps your home warm and cozy when you need it the most.
Thermostat Included
The included wired thermostat has a variety of options to keep your home the temperature you want it to be.
Optional Heating Kit
Optional heat kits available in 5kw, 8kw, 10kw, 15kw, and 20kw.
Follow Me® Function
The Central Ducted Hyper Heat will track the air temperature around you using the remote to ensure you receive maximum comfort.
Thermostat Compatibility
Different Thermostat Options: Compatible with any third party thermostat including NEST® thermostats.
Gold Fin® Condenser
Live on the coast? Don’t worry, our condenser is built to resist long term corrosion.
Installation Checklist
Installing the MRCOOL Central Ducted Hyper Heat System requires careful planning and adherence to specific requirements to ensure optimal performance and efficiency. Here are the key installation requirements - Professional HVAC Technician is required:
MRCOOL Central Ducted Hyper Heat System Installation Checklist
Pre-Installation
-
Site Assessment
- Conduct a thorough assessment of the installation site.
- Ensure adequate space and clearance for indoor and outdoor units.
- Verify structural integrity of mounting locations.
-
Load Calculation
- Perform Manual J load calculation to determine proper system sizing.
-
Ductwork Evaluation
- Inspect existing ductwork for leaks, damage, or inefficiencies.
- Ensure duct system is adequately sized and sealed.
- Plan for any necessary ductwork modifications or upgrades.
Indoor Unit Installation
-
Location Selection
- Choose a central location (e.g., basement, attic, or utility room).
- Ensure the indoor unit is level and properly supported.
-
Mounting the Indoor Unit
- Secure the indoor unit to a stable surface.
-
Electrical Connections
- Ensure proper electrical supply and grounding.
- Install a dedicated 240-volt circuit.
- Connect indoor unit wiring according to manufacturer specifications.
-
Condensate Drainage
- Install condensate drain line with proper slope.
- Verify drainage to an appropriate point.
- Install condensate pump if necessary.
Outdoor Unit Installation
-
Location Selection
- Place outdoor unit on a flat, stable surface (e.g., concrete pad).
- Ensure outdoor unit is at least 12 inches above ground level.
- Maintain manufacturer-recommended clearance around unit (typically 24 inches on all sides, 60 inches above).
-
Mounting the Outdoor Unit
- Secure outdoor unit to concrete pad or mounting surface.
-
Electrical Connections
- Ensure proper electrical supply and grounding.
- Connect outdoor unit wiring according to manufacturer specifications.
Refrigerant Lines
-
Connecting Refrigerant Lines
- Use MRCOOL® No-Vac® Quick Connect® Line Set.
- Ensure lines are properly sized and insulated.
- Check for secure connections without vacuuming or flare welding.
- Ensure kink-resistant design is maintained.
-
System Charging
- Verify refrigerant levels.
- Check for leaks in the refrigerant lines.
Ductwork Integration
-
Connecting to Ductwork
- Connect indoor unit to existing or new ductwork.
- Ensure all connections are sealed with mastic or foil tape.
- Install supply and return air plenums as needed.
System Testing and Final Checks
-
System Testing
- Test system operation in heating and cooling modes.
- Verify proper refrigerant levels and electrical connections.
- Measure airflow and temperature differentials.
- Ensure thermostat functionality.
-
User Instructions
- Provide homeowner with system operation instructions.
- Explain the use of smart thermostat and remote controls.
- Discuss regular maintenance needs (e.g., filter changes, inspections).
-
Maintenance Schedule
- Set up a maintenance schedule for regular system checks and servicing.
Post-Installation
-
Warranty Activation
- Ensure 10-year warranty for compressor, parts, and labor is in place.
- Confirm no registration process is needed; labor warranty is automatically activated upon installation.
-
Final Inspection
- Perform a final inspection of the entire system.
- Ensure all components are securely installed and operating correctly.
- Clean up the installation site.
Following this comprehensive checklist will ensure that the MRCOOL Central Ducted Hyper Heat System is installed correctly and efficiently, providing reliable performance and optimal comfort for years to come. Always refer to the installation manual for specific details and guidelines. Hiring a certified HVAC professional is recommended to guarantee all requirements are met.
Specifications
MRCOOL® Hyper Heat Central Ducted Specs
SEER2 |
17.4 |
EER2 |
11.7 |
HSPF2-4 |
10 |
HSPF2-5 |
8 |
CFM |
3000 |
COOLING CAPACITY (BTU) |
24000 |
HEATING CAPACITY (BTU) |
24000 |
VOLTAGE (V) |
208-230 |
PHASE |
1 |
CYCLE |
60 |
MAX FUSE BREAKER (A) |
35 |
MIN CIRCUIT AMPACITY (A) |
20.5 |
REFRIGERANT TYPE |
R-410A |
REFRIGERANT VOLUME (OZ) |
102.29 |
DECIBEL RATING (DBA) |
62 |
INVERTER |
DC |
MAX LINESET LENGTH (FT) |
164.04 |
LIQUID LINE SIZE |
3/8 |
SUCTION LINE SIZE |
3/4 |
AUXILIARY HEATER INCLUDED |
No |
AUXILIARY HEATER AVAILABLE |
Yes |
UL LISTED |
Yes |
ENERGY STAR CERTIFIED |
Yes |
AHRI CERTIFIED |
Yes |
BASE WARRANTY |
10yrs Parts and Labor |
PROPOSITION 65 WARNING |
Yes |
NET DEPTH (IN) |
16.14 |
NET HEIGHT (IN) |
31.89 |
NET WIDTH (IN) |
37.24 |
NET WEIGHT (LBS) |
136.69 |
GROSS DEPTH (IN) |
19.88 |
GROSS HEIGHT (IN) |
35.04 |
GROSS WIDTH (IN) |
42.91 |
GROSS WEIGHT (LBS) |
146 |
Maintenance Tips
Maintenance Tips for MRCOOL Central Ducted Hyper Heat System
Regular maintenance of the MRCOOL Central Ducted Hyper Heat System is crucial to ensure optimal performance, energy efficiency, and longevity. Here are some maintenance tips to keep your system running smoothly:
Monthly Maintenance
-
Air Filter Inspection and Replacement
- Check Filters: Inspect air filters monthly and replace them if they are dirty or clogged.
- Replacement Schedule: Replace filters every 1-3 months, depending on usage and indoor air quality.
Quarterly Maintenance
-
Outdoor Unit Inspection
- Clear Debris: Remove leaves, dirt, and debris from around the outdoor unit to maintain proper airflow.
- Check Unit: Inspect the outdoor unit for any visible damage or obstruction.
-
Indoor Unit Inspection
- Clean Vents: Ensure that all supply and return vents are clean and unobstructed.
- Inspect Components: Check for any visible signs of wear or damage to the indoor unit components.
Biannual Maintenance
-
System Cleaning
- Evaporator and Condenser Coils: Clean the evaporator and condenser coils to improve efficiency and prevent system strain.
- Condensate Drain: Inspect and clean the condensate drain line to prevent clogs and water damage.
-
Thermostat Check
- Test Thermostat: Ensure the thermostat is functioning correctly and accurately controlling the system.
- Replace Batteries: Replace thermostat batteries if necessary.
Annual Maintenance
-
Professional Inspection
- Hire a Professional: Schedule an annual inspection and maintenance service with a certified HVAC technician. They will perform a comprehensive check and service of the entire system.
-
Refrigerant Levels
- Check Refrigerant: Have a professional check refrigerant levels and adjust if necessary to ensure efficient operation.
-
Electrical Connections
- Inspect Wiring: Check all electrical connections for signs of wear, corrosion, or looseness, and have a professional address any issues.
-
Ductwork Inspection
- Inspect and Seal: Inspect ductwork for leaks, damage, or disconnections. Seal any leaks with mastic or foil tape to improve efficiency.
As Needed Maintenance
-
Addressing Unusual Noises or Performance Issues
- Monitor System: Pay attention to any unusual noises or changes in system performance. Unusual sounds, reduced airflow, or inconsistent temperatures may indicate a problem.
- Immediate Action: Address any issues promptly to prevent further damage. Contact a professional if you are unsure how to proceed.
-
Updating System Software
- Smart Controls: If your system includes smart controls or a connected thermostat, ensure that the software is up-to-date to take advantage of new features and improvements.
General Tips
-
Maintain Clearance
- Outdoor Unit Clearance: Keep at least 24 inches of clearance around the outdoor unit and 60 inches above it to ensure proper airflow and efficient operation.
- Indoor Unit Access: Ensure there is adequate space around the indoor unit for maintenance and inspection.
-
Monitor Energy Bills
- Energy Usage: Monitor your energy bills for any unexpected increases, which could indicate a decrease in system efficiency.
-
Documentation
- Keep Records: Maintain a log of all maintenance activities, including dates and details of inspections, cleanings, and repairs. This helps in tracking the system’s health and scheduling future maintenance.
-
Manufacturer’s Manual
- Follow Guidelines: Always refer to the manufacturer’s manual for specific maintenance guidelines and recommendations.
Regular maintenance of the MRCOOL Central Ducted Hyper Heat System is essential to ensure its efficient operation and longevity. By following these tips and scheduling professional inspections, you can keep your system running smoothly, save on energy costs, and maintain a comfortable indoor environment year-round.